The papimi DELTA sets new standards in Ion-Induction-Therapy with its sophisticated and powerful technology. The versatile accessories enable numerous forms of treatment in human and veterinary medicine.
The papimi DELTA stands for:
Variable pulse rates and power levels
The papimi DELTA stands for:
Over 30 years of service and experience
The papimi DELTA stands for:
Quality according to the patented original by Prof. DDr. P. Pappas
The papimi DELTA stands for:
A wide range of applications for Physical Cell Therapy
The papimi DELTA stands for:
Short, painless and athermal forms of therapy
The papimi DELTA stands for:
Easy to use when clothed
The papimi DELTA stands for:
Plasma chamber for generating special bioresonance pulses
The papimi DELTA creates high intensity electromagnetic impulses by discharging capacitors via a plasma chamber. A high voltage of 40 kV and peak currents of about 10 kA result in an energy output of 96 J. A pulsed magnetic field is thus emitted with intensity in the range of 48-110 mT in the vicinity of the applicator coil.
Each impulse lasts about 50 μs and comprises high-frequency spikes on a continuous spectrum in the kHz to MHz range, with the peak intensity at 150-250 kHz. The device features a user-selected pulse rate from 1 to 8 Hz, or can be operated at a variable pulse rate.
Pulses induce weak electric currents deep in the tissues (eddy currents), of the same frequencies, affecting cell energy and membrane potential – this whole process works athermally and can be carried out while patients are clothed.
100/120, 230/240 VAC, 50/60 Hz
10/15 amps, slow acting, low breaking capacity.
1.5 KW max.
Damped sine wave
(Oscillation frequency: 150-250kHz)
Electromagnetic field frequency spectrum: 0.15-300MHz
(after applying Fast Fourier Transform on the waveform)
Intensity of 48-110mT (time varying)
Pulse production rate: 1-8 Pulses Per Second (pps)
50 μs, Peak duration < 1 μs,
repetitive 500 ms at 2 pps
High selection: 96 Joules max,
Normal selection: 2/3 of High selection
Low selection: 1/3 of High selection
96 Joules per pulse (pps at high);
54 (pps watts at normal)
Effective or Average voltage 18 volts, along the perimeter of the loop within 18 cm distance.
Closed induction coil, 20-22 cm dia., local field1, and non-radioactive2
Within 15 cm at full power, diminishing proportionally to the third power of distance
Low (DELTA only) , Normal, or High
Pulses per second rate adjustable by automatic electronic control.
Pulses per second rate adjustable by automatic electronic control.
Double pole, illuminated
“START/STOP” push buttons. The device stops functioning automatically after timer command or after pressing “STOP’, or by any power failure or malfunction.
Small quantity of ozone (O3) and optionally ventilation exhaust to outside of the building.
Approximately 100 kg
106 cm x 62 cm x 56 cm (H x L x W)
Leakage Current Detector and Shut-off Mechanism. Temperature Control and Overheat Thermal Shut-off Mechanism.
The device is tested at ± 15 kV for air discharge and ± 8 kV for contact discharge.
Manufactured for Category II (2.5kV) mains transients.
The device is tested for Electrical safety and Electromagnetic Compatibility (EMC), according to EN60601-1 and EN60601-1-2.
Operating: from 0℃ to 36℃.
Maximum humidity < 80%.
Storage: from – 5℃ to 45℃.
Maximum humidity < 80%.
1 Power drops off proportionally to the third power of distance. This defines a non-radiative local field.
2 Reminder: Electromagnetic Radiation fields drop off proportionally to the second power of distance.
The papimi therapy device guarantees the highest level of quality, functionality and safety: